ProSoft Technology's EtherNet/IP® to CC-Link communication gateway allows Rockwell Automation® control platform users to integrate CC-Link Master compatible products with existing EtherNet/IP control networks.
The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol and is user-configurable as both a Client and/or a Server. As a Client, the gateway can send commands and manage data flow among a large number of devices on the EtherNet/IP network. As a Server, the gateway can provide concurrent data transfer to multiple Clients.
The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network.
Powerful network integration |
|
EtherNet/IP |
|
CC-Link Intelligent or Local Station |
|
Backed by ProSoft Technology® |
|
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.
ProLinx® Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today’s most widely used industrial automation.
The EtherNet/IP protocol is one of the primary connectivity tools used by different Rockwell Automation® platforms.
The Explicit Messaging aspect of the protocol has been implemented to provide asynchronous data transfer between the ProLinx gateway and Rockwell Automation hardware
Supported PLC Types | PLC-2®, PLC-3®, PLC-5®, SLC™500, ControlLogix™, CompactLogix™, and MicroLogix™ |
Messaging Types | As a Client, PCCC Explicit Messaging As a Server, PCCC or CIP Explicit Messaging |
Command Sets |
PLC-2/PLC-3/PLC5 Basic Command Set |
CC-Link (Control & Communication Link) is an open-standard-based communication protocol that enables easy connection to Mitsubishi and other Master PLCs.
In Server mode, the gateway accepts messages from one or more Clients that want to read data from or write data to the gateway's internal memory database.
Miscellaneous | Binary, Integer or Floating point data supported, as well as other special data types, like timers, counters, ASCII files and more |
EtherNet/IP Server | Five independent TCP/IP Server sockets permit multiple Clients to see and change all user data contained in the gateway. The Server supports CIP and PCCC Explicit Message connections from EtherNet/IP Clients. |
PCCC Data File Emulation |
Data Table File Size: 100 or 1000 words N10 to N19, based on file set to 1000 (Other data table types also supported) |
CIP Services Supported | 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write |
In Client mode, the gateway controls read and write data transfers between the itself and other EtherNet/IP devices. Data transfer can be initiated and executed with no logic programming required in the target Rockwell Automation hardware.
EtherNet/IP Client | Three simultaneous Client connections |
Command List | Each Client supports up to 100 read or write commands per Client, allowing up to three concurrent connections with Ethernet/IP devices. |
Command Poll List | User can enable or disable polling on a per-command basis, as well as choose to write continuously or only on change of data. |
Configurable Parameters | Number of commands (Up to 100 per client) Min Command Delay Response Timeout Retry Count (and much more) |
CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing its I/O data transfer capacity.
Maximum Number of Occupied Stations | 4 stations, consecutive addresses |
Maximum Number of Devices per network | 26-64 Devices depending on Local and Slave Stations configured |
Device Types Supported | Intelligent Device and Local Station |
CC-Link Version supported | CC-Link Version 1.10 cyclic data transmission |
Message handling | Cyclic Messages and Transient Messages |
Cyclic Data Capacity |
24 input data words and 24 output data words. |
Additional I/O Data Transfer Capacity | Transient Messaging extends the data transfer capacity to more than 8,000 additional words |
Transient Message Commands | System Information, Memory Access Information, RUN, STOP, Line Test. Memory Read and Memory Write commands |
Communication speed | 10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps |
Transmission path format | Bus format (EIA RS485 conformance) |
Transmission format | HDLC conformance |
Error control system | CRC (X16+X12+X5+1) |
Power Supply |
24 VDC nominal |
||||||||||||
Current Load | 500 mA [email protected] 32 VDC max |
||||||||||||
Operating Temperature | -20 to 50°C (-4 to 122°F) |
||||||||||||
Storage Temperature | -40 to 85°C (-40 to 185°F) |
||||||||||||
Relative Humidity | 5% to 95% (non-condensing) |
||||||||||||
Dimensions |
Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) |
||||||||||||
General LED Indicators |
Power and General Status |
||||||||||||
CC-Link LED Indicators |
Run (Network Status) |
||||||||||||
Configuration Serial Port |
DB-9M RS-232 only |
||||||||||||
Ethernet Port | RJ45 Connector, 10Mbit, half-duplex only Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
||||||||||||
CC-Link Interface |
|
||||||||||||
Shipped with Each Unit |
Mini-DIN to DB-9M serial cable |
Declaration of Conformity (RoHS/CE) | 299,63 kB | Последнее изменение 04.03.18 |